MOD (Model): UVC 568340315505A P → Model/Type number of the motor. • HP (Horse Power): 2 → Motor power is 2 horsepower. • PH (Phase): 1/2 → Indicates that the motor can operate on single phase (Single Phase) or two phases (depending on connection). • VOLT (Voltage): 115/230 or 110/208-220 → Can operate at multiple voltage levels (single or three phase). • FL. AMP (Full Load Amps): 20/10.3 or 10.7/6.8/4.8 → Current consumption under full load. • DUTY: CONT → The motor is designed for continuous operation (Continuous Duty). • AMB: 40°C → Maximum allowable ambient operating temperature (40 degrees Celsius). • S.F. (Service Factor): 1.25 → Means the motor can handle 125% of its rated capacity for a limited period without damage. • FR (Frame): 56C → Motor size and frame (important for mounting and dimensions). • RPM (Revolutions Per Minute): 3450/2850 → Two possible motor speeds (high speed and low speed). • Insul. Class (Insulation Class): B → Thermal insulation type for internal windings. • Hz (Frequency): 50/60 Hz → Operates on power networks with frequency of 50 or 60 Hz. • Part No.: 4261 → Part/Manufacturing number.